Nexans YMz1K Cca ULTIMO MOBIWAY 0.6/1 kV

Products

YMz1K Cca ULTIMO 0.6/1kV 3G2.5 MOBIWAY150 To be removed

Nexans ref. 10593269

  • Packaging: Drum (150m)
  • Core identification: Blue, brown, green / yellow
  • Number of cores: 3
  • Nominal outer diameter: 11.6 mm
  • Approximate weight: 250 kg/km

 

YMz1K Cca ULTIMO 0.6/1kV 5G2.5 MOBIWAY100 To be removed

Nexans ref. 10593300

  • Packaging: Drum (100m)
  • Core identification: Blue, brown, black, grey, green / yellow
  • Number of cores: 5
  • Nominal outer diameter: 14.7 mm
  • Approximate weight: 340 kg/km

 

Description

Description

Standards

  • Product
    HD 604.4D; IEC 60228; IEC 60502

MOBIWAY MOB

The YMz1K Cca ULTIMO MOBIWAY Mob is a MOBIWAY™ Mob drum with the standard installation cable YMz1K Cca. This innovative new MOBIWAY™ MOB system is available for the most common types of YMvK Dca and YMz1K Cca and are compatible with the ##link:MOBIWAY™ Mob systeem## of reusable flanges. Also available for MOBIWAY MOB: signal cables & fire alarm cables.

Main benefits

  • Easy unwinding, even in difficult conditions like in aerial work platforms
  • Thanks to integrated handles easy movable around the work site
  • Connect several MOBIWAY MOB systems and install more cables at the same moment

Guide to use

  • Place a MOBIWAY-MOB flange on the MOBIWAY drum and pull the socket down. 
  • Lock the flange with the Super Locker. Do the same with the other side.
  • Carry the system to the workplace - alone or with 2, depending on the weight.
  • Set the reel down and combine with another MOBIWAY set if necessary.
  • Simply unwind the cable(s)!

Is the drum empty? Unclip the MOBIWAY flanges and use them again on another MOBIWAY drum.

Key features of Nexans ULTIMO

  • Faster stripping: up to 80% time savings thanks to the optimized sheath
  • Improved safety: one cut and bend are enough – reducing the risk of injury or conductor damage
  • UV-resistant: suitable for outdoor use, our ables passed the 720 hour test standard EN 50289-4-17 Method A
  • With EPD Environmental Product Declaration: PEP EcoPassport provides full insight into the ecological footprint of the cables

Benefits for the installer

Nexans YMz1K Cca ULTIMO on MOBIWAY Mob drums combines speed, ease of use and sustainability – exactly what you need on today’s jobsite. Ask for it at your wholesaler.

Cable Application

Nexans YMz1K Cca ULTIMO 0.6/1 kV is a power cable  for general use in construction works subject to performance requirements on reaction to fire. YMz1K Cca ULTIMO 0.6/1 kV is suitable for application in low voltage installations up to 0.6/1 kV, according to NEN 1010. It meets the requirements according to fire classification Cca-s1,d1,a1 for usage in buildings and civil engineering works with a medium fire hazard level (NEN 8012).

Design

  1. Conductor: Bare copper, solid, class 1
  2. Insulation: XLPE
  3. Inner covering: filling compound 
  4. Outer sheath: PVC
  5. Colour: Grey

Installation

  • In cable duct
  • In cable tray
  • In open air if protected from direct UV rays
  • Embeded in concrete or cement or walls
  • No ground laying without protection
  • In industries

Characteristics

Characteristics

Construction characteristics

Construction characteristics

With Green/Yellow core
Yes
Sheath colour
Grey
Conductor material
Bare copper
Conductor flexibility
Solid class 1
Conductor shape
Round solid
Insulation
XLPE (Cross-linked Polyethylene)
Outer sheath
Halogen free compound
Lead free
Yes

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
2.5 mm²

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV
Permissible current rating in open air
32 A

Mechanical characteristics

Mechanical characteristics

Impact resistance Max (IEC 30364-5-51)
- J

Usage characteristics

Usage characteristics

Length
- m
Packaging
MOBIWAY™Refill
Field of application
Standard
Operating temperature, range
-20 ... 80 °C
Minimum installation temperature
0 °C
Max. conductor temperature in service
90 °C
Resistance to vibrations
Moderate
One single bending at each end minimum
8 (xD)
U.V resistance
EN 50289-4-17 method A, for 720h

Resources

Resources

Selling & delivery Information

YMz1K Cca-s1,d1,a1  [n]G2,5 mm²
DOP Ref: [number] 
NEXANS ULTIMO  
KEMA KEUR

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close