English Inloggen Registreren Zoek in de catalogus Neem contact met ons op
Global expert in cables and cabling system

Over Nexans

Produkten & Oplossingen

Klantenservice

Werken bij Nexans

Nieuws - Pers

Zoeken

BL-02XS(St)CHXOE 1 P AWG 20 WTB/ MVB

Bookmark printen Contact
BL-02XS(St)CHXOE 1 P AWG 20 WTB/ MVB Databus for rolling stock WTB halogen free
Standaarden
Internationaal  EN 50267-2-2
Nationaal  DIN 5510-1
Beschrijving

Application

The cable BL-02XS(St)CHXOE 1 P AWG 20 is used as a connecting cable to transmit digital signals inside railway rolling stock.

Marking

Continuos printing in contrasting colors [ manufacturer identification ] + type identification resp. manufacturers identification thread

Core colours

Pair: white, black

Standard

DIN 5510 part 1

Hazard level 1 - 4

Design

Conductor/ core: Tinned Cu strand, AWG 20/ 19

Insulation: Foam Skin-Polyethylene, cross-linked

Pair: Two cores were stranded to a pair together with two filling elements

Wrapping: Minimum one layer of non woven tape wrapped overlapped

Screen: Screen composed of a aluminium luminated plastic foil and a tinned copper braid, optical coverage approx. 90%

Seperator; Non woven tape overlapped

Outer sheath:  Cross linked mineral il and fuel resistant HFFR Compound EM 104 according to EN 50264 part 1

Colour: black

 


 TOP
Karakteristieken
Constructie
Halogeenvrij PE sheathed  
Afmetingen
Geleiderdoorsnede 0,62mm²  
Gewicht, benaderd 80kg/km  
Gebruik
Rookdichtheid EN/IEC 61034-2  
Gebruikstemperatuur van/tot -40 .. 90°C  
Corrosie dmv gassen No acc. to EN 50267-2-2  
Toxiciteit van gassen innocuous EN 50305-9.2  
Niet brand voortplantend ("mb") Ja  

 TOP
Uw keuze   1/1
Selecteer alle items Nexans ref. Naam
Make to order product 45983010 BL-02XS(St)CHXOE 1 P AWG 20 WTB/ MVB
Voeg toe aan favorieten

 TOP
BL-02XS(St)CHXOE 1 P AWG 20 WTB/ MVB

Maximum admissible operating temperature at the conductor

in operation 

 - 40°C / + 85°C

during laying

 - 20°C / + 50°C

 

Minimum admissible bending radius

Single bending

≥ 6 x D

Multiple bending

≥ 12 x D

Max. admissible tensile loading

50 N/mm² conductor cross-section

 

Properties

 

Requirements

Test according to

Electrical properties

Test voltage

core / core

2000 Veff

EN 50289-1-3

 

core / screen

1500 Veff

50 Hz, 1 min

 

Conductor resistance

≤ 33.1 Ω / km

EN 50289-1-2

 

Mean characteristic impedance

0.5 - 2 MHz

( 120 ± 12 ) Ω

IEC 61196-1 part 11.8.1

 

Attenuation

1.0 MHz

≤ 1.1 dB / 100 m

EN 50289-1-8

 

2.0 MHz

≤ 1.5 dB / 100 m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


 TOP
Informatie over verkoop/levering
This cable is neither useful for mutiple bendings nor for torsion. If needed any single case must be decided.

Nexans © copyright 2001 - 2012   Legal Notice | Neem contact op | Site Map