English Inloggen Registreren Zoek in de catalogus Neem contact met ons op
Global expert in cables and cabling system

Over Nexans

Produkten & Oplossingen

Klantenservice

Werken bij Nexans

Nieuws - Pers

Zoeken

BL-02XS(ST)CHX MVB

Bookmark printen Contact
BL-02XS(ST)CHX MVB Databus for rolling stock, halogen free
Standaarden
Nationaal  DIN 5510-1
Beschrijving

Application

Connecting cable for the transmission of digital signals up to 10 M Baud in railway rolling stock.

Cable marking

continuos printing in contrasting colors [manufacturer identification] +
type identification resp. manufacturers identification thread (distance max. 500 mm)

Core colours
pair 1: red, black
pair 2: white, yellow

Standards

DIN 5510 part 1

Hazard level 1 - 4

 


 TOP
Karakteristieken
Constructie
Afscherming Alu-folie + vertind koperen omvlechting  
Halogeenvrij PE  
Afmetingen
Geleiderdoorsnede 0,5mm²  
Aantal paren 2  
Aantal quads 1  
Buitendiameter, nominaal 8,0mm  
Elektrische eigenschappen
Karakteristieke weerstand 120Ohm  
Mechanische eigenschappen
Maximum tensile load 50N  
Gebruik
Fire load 0,272MJ/km  
Corrosie dmv gassen Nee  
Toxiciteit van gassen innocuous EN 50305  
Niet brand voortplantend ("mb") Ja  

 TOP
Zoeken op parameters
Gewicht, benaderd  kg/km
Uitvoeren
Reset
Uw keuze   1/1
Selecteer alle items Nexans ref. Naam Gewicht, benaderd (kg/km)
Make to order product 45953050 BL-02XS(ST)CHX MVB 2 x 2 x 0.5 89
Voeg toe aan favorieten

 TOP
BL-02XS(ST)CHX MVB

Properties 

 

Requirements

Test according to

Electrical properties 

 

 

 

test voltage

core/core

1000 Veff

EN 50289-1-3

 

core/screen

1500 Veff

50 Hz, 1min. 

conductor resistance

 

≤ 41Ω/km

EN 50289-1-2

mean characteristic impedance 

0.5 MHz - 2 MHz

(120±12) Ω

IEC 61196-1 part 11.8.1

Attentuation 

1.0 MHz

≤ 1.2 dB/100m

EN 50289-1-8

 

1.5 MHz

≤ 1.5 dB/100m

 

 

2.0 MHz

≤ 1.7 dB/100m

 

 

3.0 MHz

≤ 2.1 dB/100m

 

Maximum admissible operating temperature at the conductor

 

 

 

Category temperature 

in operation

-40°C to +85°C

 

 

during laying

-20°C to +50°C

 

Minimum admissible bending radii

 

 

 

Single bending

≥ 5D

Multiple bending

≥ 10D

Max. admissible tensile load

50N/mm² conductor cross section

D = cable diameter

 

 

 


 TOP
Informatie over verkoop/levering
This cable is neither useful for multiple bendings nor for torsion. If needed any single case must be decided.

Nexans © copyright 2001 - 2012   Legal Notice | Neem contact op | Site Map