FLAMEX BLG - screened single core cable In line with SNCF 10-5249-367 or SNCF 10-5315-848 or NFF 63 826
Screened and halogenfree single core cable for flexible applications
1,5 kV or 3 kV (Vo)
Standaarden
Internationaal  EN 50264; EN 50382-2
Beschrijving

Applications

For protected installation in railway vehicles (locomotives, trains, trolley busses), switching stations and control panels. Installation in cable ducts, pipes and tubes. Specially for mobile links between cars or car bogies. 

This cable will be specially design in line to SNCF 10-5249-367 resp. SNCF 10-5315-848 resp. NFF 63 826 acc. to the customers demand.

Design

1. Conductor

Flexible or extra flexible stranded tinned copper, class 5 resp. 6
acc. to DIN VDE 0295 / IEC 60228 / HD 383,
conductor wrapping optional.

2. Insulation

Cross linked compounds
type EI104 (rubber) or
type EI112 (silicone) 

3. Separtor

Tape or foil

4. Screen

Tinned Cu wire braid or
textil braid

5. Separator

Tape or foil

6. Sheath

cross linked compound type EM104, black

 

Testing procedures must be defined with the customers.
 


 TOP
Karakteristieken
Gebruik
Gebruikstemperatuur van/tot -40 .. 90°C  
Corrosie dmv gassen No acc. to EN 50267-2-2  
Toxiciteit van gassen innocuous EN 50305-9.2  
Niet brand voortplantend ("mb") EN 60332-1-2 & EN 60332-3-24 & EN 60332-3-25  
Rookdichtheid EN 50268-2; NFF 16101  
Buigradius na aanleg 5(xD)  
Buigradius bij aanleg 10(xD)  
Oliebestendigheid EN 60811-2-1  
Ozonbestendigheid Ja  
UV-bestendigheid Ja  

 TOP
Max. operating temperature at conductor

Conductor at normal operation

≤ 90 °C

Conductor under short-circuit conditions (tinned)

≤ 200 °C