RHEYHALON (N)SHXAFCOE 1.8/3 (3.6) kV

Bookmark printen Contact
RHEYHALON (N)SHXAFCOE 1.8/3 (3.6) kV EN 50264-3-1, tab. 3
Halogenfree screened and sheathed single core cable
1,8/3 kV
Standaarden
Internationaal  EN 50264-3-1
Beschrijving

Applications

For use in railway vehicles (trains, locomotives, trolleybusses, etc.), switching stations and control panels.

Installation in cable ducts, tubes and outside. For wiring in switching stations and distribution boards up to 1000 V, this cable is short-circuit and earth fault save.

Current-carrying capacity acc. to EN 50343 as well as VDE 0298 part 4.
Satisfies performance requirements acc. to EN 45545-1.

This product is also part of our WINDLINK® offer dedicated to wind turbines.

Design

1. Conductor
Flexible stranded tinned copper, acc. to DIN EN 60228 class 5.

2. Insulation
Doublelayer insulation, type EI110/EI109 (EM104) acc. to EN 50264-1
oil- and diesel-oil resistant

3. Separator
Optional foil or tape 

4. Screen
Tinned copper wire braid, covering app. 85%

5. Separator
Optional foil or tape

6. Outer sheath
Special cross-linked EVA,  type EM104 acc. to EN 50264-1,
oil,  diesel-oil, ozone and uv resistant

 

Cable marking

Ink marking white, e.g.:

RHEYHALON VDE-Reg.-Nr. 9682 (N)SHXAFCOE 1.8/3 kV EN 50264-3-1
1800 V 35 MM S FA-Nr. ...

Standards

DIN 5510 part 1, flame protection class 1, 2, 3 and 4; BS 6853


 TOP
Karakteristieken
Constructie
Halogeenvrij IEC 60754-1  
Gebruik
Gebruikstemperatuur van/tot -40 .. 90°C  
Corrosie dmv gassen No acc. to EN 50267-2-2  
Toxiciteit van gassen innocuous EN 50305-9.2  
Niet brand voortplantend ("mb") EN 60332-1-2 & EN 60332-3-24 & EN 60332-3-25  
Rookdichtheid EN/IEC 61034-2  
Buigradius na aanleg 6(xD)  
Buigradius bij aanleg 10(xD)  
Oliebestendigheid Ja  
Ozonbestendigheid Ja  
UV-bestendigheid Ja  

 TOP
Electrical properties

Nominal voltage 

Uo/U (Umax) = 1.8/3 (3.6) kV

Max. operating voltage in d.c. installations, one-sided earthed                                                              

Uo= 2.7 kV DC

Testing a.c. voltage (5 minutes) 

U = 6.5 kV

Coupling resistance 10 kHz – 30 MHz 

≤ 50 Ohm/km


Max. operating temperature at conductor

Conductor at normal operation

≤ 90 °C/250.000 h

 

≤ 120 °C/20.000 h

Overload 

≤ 160 °C / 50 h

Conductor under short-circuit conditions (tinned)

≤ 200 °C


 TOP
Informatie over verkoop/levering
  • Other cross-sections on request.

  • Special conditions relating temperature and bending radii (e.g. by compelled guidance into cluthes, wagontransition and boogies) on request.