RHEYHALON 4GKW-EN 1,8/3(3,6)kV

Bookmark printen Contact
RHEYHALON 4GKW-EN 1,8/3(3,6)kV EN 50264-3-1, tab. 2
Halogenfree single core cable
1,8/3 kV
Standaarden
Internationaal  EN 50264-3-1
Beschrijving

Applications

For protected installation in railway vehicles (locomotives, trains, trolley busses), switching stations and control panels. Installation in cable ducts, pipes and tubes.
Current carrying capacity acc. to EN 50343 as well as VDE 0298 part 4.
Serves request acc. to EN 45545-1.

 

Design

1. Conductor

Flexible stranded tinned copper, class 5 acc. to DIN VDE 0295 / IEC 60228
/ HD 383, conductor wrapping optional.

2. Insulation

Double layer insulation, rubber type EI110/EI109 (EM104)  acc. to EN 50264-1,
oil, diesel-oil, ozone and UV-resistant

 

Cable marking

e.g.:    RHEYHALON VDE-Reg.-Nr. 7904 4GKW-EN 1,8/3 kV EN 50264-3-1 
           1800V  1x25 OM  FA-Nr. ...
 

Core colours

Black (BK)
 

Additional standards

DIN 5510 part 1: Flame protection class 1, 2, 3 and 4
BS 6853 (on request)


 TOP
Karakteristieken
Constructie
Halogeenvrij IEC 60754-1  
Gebruik
Gebruikstemperatuur van/tot -40 .. 90°C  
Corrosie dmv gassen No acc. to EN 50267-2-2  
Toxiciteit van gassen innocuous EN 50305-9.2  
Niet brand voortplantend ("mb") EN 60332-1-2 & EN 60332-3-24 & EN 60332-3-25  
Rookdichtheid EN/IEC 61034-2  
Standaard EN  
Buigradius na aanleg 5(xD)  
Buigradius bij aanleg 10(xD)  
Oliebestendigheid Ja  
Ozonbestendigheid Ja  
UV-bestendigheid Ja  

 TOP
Zoeken op parameters
Kleur  
Geleiderdoorsnede  mm²
Buitendiameter, minimum  mm
Buitendiameter, maximum  mm
Fire load  kWh/m
Gewicht, benaderd  kg/km
Uitvoeren
Reset
Uw keuze   11/11
Selecteer alle items Nexans ref. Kleur Geleiderdoorsnede (mm²) Buitendiameter, minimum (mm) Buitendiameter, maximum (mm) Fire load (kWh/m) Gewicht, benaderd (kg/km)
79471306 Zwart 25 10,3 10,9 0,4 290
79471307 Zwart 35 11,4 12,0 0,46 400
79471308 Zwart 50 13,3 13,9 0,6 550
79471309 Zwart 70 15,3 15,9 0,75 750
79471310 Zwart 95 17,0 17,6 0,85 970
79471311 Zwart 120 19,3 19,9 1,1 1250
79471312 Zwart 150 21,6 22,2 1,35 1550
79471313 Zwart 185 23,5 24,1 1,5 1900
79471314 Zwart 240 26,6 27,2 1,9 2450
79471315 Zwart 300 29,3 30,1 2,2 3050
79471316 Zwart 400 34,1 34,9 3,5 4000
Voeg toe aan favorieten

 TOP
Electrical properties

Nominal voltage 

Uo/U (Umax) = 1,8/3 (3,6) kV

Max. operating voltage (d.c.)                                                         

Vo =2,7 kV 

Testing a.c. voltage (5 minutes)

U = 6,5 kV


Max. operating temperature at conductor

Conductor at normal operation

≤ 90 °C/250.000 h

 

≤ 120 °C/20.000 h

Overload 

≤ 160 °C / 50 h

Conductor under short-circuit conditions (tinned)

≤ 200 °C