MAZ CHXOE multipair

Bookmark printen Contact
MAZ CHXOE multipair Cables for Rolling Stock
Standaarden
Internationaal  EN 50264-1; EN 50267-2-1; EN 50267-2-2; EN 50305; EN 50306-2.1; EN 50343; EN 60684-2
Beschrijving

Application

As a control cable in railway rolling stock with mineral oil and fuel resistance. With reference to EN 50306 – 4 with profile MM and with reference to cable class P.

 

Cable marking Example

A three core control cable with 1,0 mm² conductor cross-section, halogen free core insulation, a copper braid and a halogen free, flame retardant outer sheath, is designated as:

3 MAZ 1,0 C HXOE

 

Core colours

up to 10 cores colored; Core: 1 - white, 2 - brown, 3 - blue, 4 - black, 5 - red, 6 - yellow, 7 - green, 8 - grey, 9 - orange, 10 - violet; >10 cores: all cores white with numbers marking.

 

Standards

DIN 5510 part 1

Hazard level 1 - 4


 TOP
Karakteristieken
Constructie
Halogeenvrij PE sheathed  
Afmetingen
Minimale isolatiedikte 0,13mm  
Elektrische eigenschappen
Nominale spanning Uo/U (Um) 300 / 300 V  
Gebruik
Max. geleidertemperatuur, in gebruik 90°C  
Corrosie dmv gassen No acc. to EN 50267-2-2  
Toxiciteit van gassen innocuous EN 50305  
Niet brand voortplantend ("mb") EN 50305  
Rookdichtheid EN/IEC 61034-2  

 TOP
Zoeken op parameters
Aantal paren  
Geleiderdoorsnede  mm²
Conductor diameter, range  mm
Diameter over external conductor / metallic screen  mm
Dikte van de buitenmantel, minimum  mm
Cable Diameter, range  mm
Gewicht, benaderd  kg/km
Fire load  kWh/m
Uitvoeren
Reset
Uw keuze   11/11
Selecteer alle items Nexans ref. Aantal paren Geleiderdoorsnede (mm²) Conductor diameter, range (mm) Diameter over external conductor / metallic screen (mm) Dikte van de buitenmantel, minimum (mm) Cable Diameter, range (mm) Gewicht, benaderd (kg/km) Fire load (kWh/m)
Make to order product 45982010 2 0,5 0,8 .. 0,95 5,6 0,5 6,6 .. 7,4 76 0,18
Make to order product 45981710 3 0,5 0,8 .. 0,95 6,0 0,5 7,1 .. 7,9 89 0,21
Make to order product 45981910 4 0,5 0,8 .. 0,95 7,0 0,5 7,6 .. 8,5 106 0,23
Make to order product 45982110 6 0,5 0,8 .. 0,95 7,8 0,5 9 .. 9,9 143 0,31
Make to order product 45989310 12 0,5 0,8 .. 0,95 11,0 0,75 12,7 .. 13,5 267 0,53
Make to order product 45981810 2 0,75 1 .. 1,15 6,3 0,5 7,4 .. 8,2 96 0,21
Make to order product 45901010 4 0,75 1 .. 1,15 7,4 0,5 8,3 .. 9,2 138 0,28
Make to order product 45989810 2 1 1,1 .. 1,3 6,8 0,5 8 .. 8,8 111 0,23
Make to order product 45989610 3 1 1,1 .. 1,3 7,4 0,5 8,5 .. 9,3 135 0,26
Make to order product 45989910 2 1,5 1,45 .. 1,6 8,6 0,5 9,5 .. 10,5 153 0,33
Make to order product 45990010 6 1,5 1,45 .. 1,6 12,2 0,7 13,2 .. 14,2 342 0,577
Voeg toe aan favorieten

 TOP
Characteristica ELCURAIL MAZ CHXOE

Maximum admissible operating temperature at the conductor

Conductor in operation

≤ 90°C / 100,000 h

Application in cold areas

> - 40°C

Minimum admissible bending radii

fixed installation

D ≤ 12 mm ≥ 3 D

D > 12 mm ≥ 4 D

operation caused movement

 

D ≤ 12 mm ≥ 5 D

D > 12 mm ≥ 6 D

D = cable diameter

Operational Conditions

nominal voltage

3000 V

test alternating voltage ( core / core ) 1 minute

2000 V / AC

current carrying capacity

according to EN 50 343


 TOP
Informatie over verkoop/levering
  • All tests were arranged on representative samples.
  • This cable is neither useful for multiple bending nor for torsion. If needed any single case must be decided.