Application
As a control cable in railway rolling stock with mineral oil and fuel resistance, according to EN 50306-4 with profile MM and cable class P.
Cable marking Example
A three core control cable with 1,0 mm² conductor cross-section, halogen free core insulation, a copper braid and a halogen free, flame retardant outer sheath, is designated as:
3 FC-X 1,0 C HXOE
Core colours
The colour of the cores is white printed with numbers.
Standards
DIN 5510 part 1 Hazard level 1 - 4 EN 50306-2 and EN 50306-4
Maximum admissible operating temperature at the conductor
Conductor in operation
< 90°C / 100,000 h
Application in cold areas
> - 40°C
Minimum admissible bending radii
fixed installation
D ≤ 12 mm 3 DD > 12 mm 4 D
operation caused movement
D ≤ 12 mm 5 DD > 12 mm 6 D
D = cable diameter
Operational Conditions
nominal voltage
300 V/ 500V
test alternating voltage (core / core) 5 minute
2000 V
currrent carrying capacity
according to EN 50 343