English Inloggen Registreren Zoek in de catalogus Neem contact met ons op
Global expert in cables and cabling system

Over Nexans

Produkten & Oplossingen

Klantenservice

Werken bij Nexans

Nieuws - Pers

Zoeken

RHEYHALON (N)TMCGCHXOE (26/45 kV)

Bookmark printen Contact
RHEYHALON (N)TMCGCHXOE (26/45 kV) In line with EN 50264 and IEC 60502
Halogenfree medium voltage cable
Standaarden
Internationaal  EN 50264; IEC 60502; Manufacturer specification
Beschrijving

Applications

For inside and outside use in railway vehicles. Installation in cable ducts or tubes.

Current-carrying capacity acc. to EN 50343 as well as VDE 0298 part 5. Satisfies performance requirements to Hazard Level 4 acc. to EN 45545-1

On request available: completely pre-assembled flexible cables with plugs and sealing ends, electrically tested.

 

Design

1. Conductor 

Flexible stranded tinned copper, acc. to DIN VDE 0295  / IEC 60228
/ HD 383 class 5

2. Inner conductive layer

conductive rubber

3. Insulation 

HEPR, type EI110 acc. to EN 50264-1
high voltage compound, ozone resistant

4. Outer conductive layer

conductive rubber (Thermo-Strip)

5. Screen

single wires, tinned (Ø 0,6 mm), separator

6. Outer sheath

Special cross-linked EVA, rubber type EM104  acc. to EN 50264-1,
oil, diesel-oil, ozone and uv resistant

 

Cable marking

Ink marking white e.g.:

RHEYHALON VDE-Reg.-Nr. 7969  (N)TMCGCHXOE 1x95mm² RF/16 25/45 kV Year

 

Additional Standards

DIN 5510 part 1, flame protection class 1, 2, 3 and 4
BS 6853


 TOP
Karakteristieken
Constructie
Halogeenvrij IEC 60754-1  
Elektrische eigenschappen
Nominale spanning Uo/U (Um) 26 / 45 kV  
Gebruik
Gebruikstemperatuur van/tot -40 .. 90°C  
Corrosie dmv gassen No acc. to EN 50267-2-2  
Toxiciteit van gassen innocuous EN 50305-9.2  
Niet brand voortplantend ("mb") EN 60332-1-2 & EN 60332-3-24 & EN 60332-3-25  
Rookdichtheid EN/IEC 61034-2  
Buigradius na aanleg 6(xD)  
Buigradius bij aanleg 10(xD)  
Oliebestendigheid Ja  
Ozonbestendigheid Ja  
UV-bestendigheid Ja  

 TOP
Electrical properties

Nominal voltage

Uo/U (Umax) = 26/45 (54) kV

Max. operating voltage

Uo max = 32 kV

Test voltage                                                              Core/Screen (5 minutes)

Uo = 70 kV

Core/Screen (1 minutes)

Uo = 75 kV

Partial discharge measurement by 52 kV,  on pre-assembled flexible cable     

≤ 5 pC


Max. operating temperature at conductor

Conductor at normal operation

≤ 90 °C/250.000 h

 

≤ 120 °C/20.000 h

Overload 

≤ 160 °C / 50 h

Conductor under short-circuit conditions (tinned)

≤ 200 °C


 TOP
Informatie over verkoop/levering
  • Other cross-sections on request.
  • Special conditions relating temperature and bending radii (e.g. by compelled guidance into cluthes, wagon transition and boogies) on request.

  • Nexans © copyright 2001 - 2012   Legal Notice | Neem contact op | Site Map