For use in railway vehicles (locomotives, trains, trolleybusses...), switching stations and control panels. Installation in cable ducts, tubes and outside. Current carrying capacity acc. to EN 50343. Werves request acc. to EN 45545-1
A 120°C conductor temperature is allowed for a 20.000 hours cumulative working time.
Design
1. Conductor
Flexible stranded tinned copper class 5 acc. to IEC 60228, optional separator tape
2. Insulation
Cross linked compound type EI109 acc. to EN 50264-1, oil and diesel-oil resistant
3. Outer sheath
Special cross-linked EVA, rubber type EM104 acc. to EN 50264-1, oil, diesel-oil, ozone and UV resistant.
e.g.: FLAMEX Z+ EN 50264-3-2 600V 2 x 1,5 MM INexansI 10/2008 FA-Nr. 0148...
black, core identification by printed numbers in white.
NFF 16101, DIN 5510 BS 6853 (on request)
Nominal voltage
Uo/U (Umax) = 0,6/1 (1,2) kV
Max. operating voltage (d.c.)
Vo =0,9 kV
Testing a.c. voltage (5 minutes)
U = 3,5 kV