Applications
For inside and outside use in railway vehicles. Installation in cable ducts and tubes.
Current-carrying capacity acc. to EN 50343. Satisfies performance requirements to Hazard Level 4 acc. to EN 45545-1.
On request available: completely pre-assembled flexible cables with plugs and sealing ends, electrically tested.
Design
1. Conductor
Flexible stranded tinned copper, acc. to IEC 60228 class 5.
2. Inner semi-conductive stress control layer
Conductive rubber
3. Insulation
HEPR, type EI 110 acc. to EN 50264-1,
high voltage compound, ozone resistant
4. Outer semi-conductive insulation shield layer
Conductive rubber (Thermo-Strip)
5. Separtor
Tape
6. Screen
Single wires, tinned (Ø 0,6 mm), separator
7. Outer sheath
Special cross-linked EVA, type EM 104 acc. to EN 50264-1,
oil, diesel-oil, ozone und uv resistant
Cable marking
Ink marking white e.g.:
FLAMEX Panto DTREN 150 018 - SNCF 10-5299319 95/16 mm2 - Cue_F
- S 26/52 kV (ww/YYYY) FA-Nr. ...
Addional Standards
NF F 16-101
|