FMKHC-F 150/250V

Bookmark printen Contact
FMKHC-F 150/250V Halogen Free, Fire Resistant Communication Cables with screen (amour) 150/250 V
Standaarden
Internationaal  IEC 60092-351; IEC 60092-359; IEC 60092-375; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Beschrijving

Applications

For fixed installations in communication, radio, control and data processing facilities on ships and offshore units in all locations and on open decks, in safety circuits where fire resistance is required.

The cables meet the flame test requirements for bunched cables acc.to IEC 60332-3 and IEEE 45-18.13, and perform to the SOLAS requirements.

All cables materials are free of halogens. No off-splitting of corrosive gases occurs in case of fire. The off-splitting of toxic gases is minimized. Therefore, these cables are especially suitable for the installation on passenger ships.

Design

  1. Conductor: stranded bare copper (7 wires) class 2
  2. Insulation: mica tape + XLPE
  3. Laying up: pair stranding (2 pair cable = quad stranding)
  4. Armouring: separator tape, bare copper braid, separator tape (optional)
  5. Outer sheath: polyolefin, orange

Marking

e.g.: l NEXANS l FMKHC 250 V 90°C IEC 60092-375 IEC 60332-3-22 IEC 60331 HALOGENFREE 19x2x0,75 mm2 + Metric Marking

 

Core Identification

Colour of each pair: black-blue
The cores or each pair are printed with same numbers, starting in centre with number 1
2 pair cable (quad):
black / brown / blue / grey


 TOP
Karakteristieken
Constructie
Geleidermateriaal Blank koper  
Samenstelling geleider Geslagen, klasse 2  
Isolatie Pole mounted  
Afscherming/bewapening Blank koperen omvlechting  
Buitenmantel Vertind koper  
Halogeenvrij IEC 60754-2  
Elektrische eigenschappen
Nominale spanning Uo/U (Um) 150 / 250 V  
Testspanning 1500V  
Gebruik
Max. geleidertemperatuur, bij kortsluiting 250°C  
Installatietemperatuur, minimum -10°C  
Gebruikstemperatuur, minimum -35°C  
Max. geleidertemperatuur, in gebruik 90°C  
Niet brand voortplantend ("mb") IEC 60332-3 Cat. A  
Vuurbestendigheid IEC 60331-21  
Rookdichtheid IEC 61034  
Corrosie dmv gassen Nee IEC 60754-2  
Toxiciteit van gassen Geen toxiciteit vlgs IEC 60754-1  
EMI-bestendigheid Ja  

 TOP
Additional Cable Characteristic

Minimum internal bending radius

 

- For all diameter

6 x cable diameter

 

 

Conductor resistance

≤ 26.0 Ohm / km

Insulation resistance

> 1100 MOhm x km

Transfer impedance at 10 MHz

 

1- and 2- pair cable

< 80 mOhm / m

4-pair cable

< 60 mOhm / m

7- to 24-pair cable

< 50 mOhm / m

 

 

Current ratings for continuous operation and further hints for cable installation

 

are according to IEC 60092-352

 


Approval

Type Approval Certificates   

 

• American Bureau of Shipping

 

• Bureau Veritas

 

• Det Norske Veritas 

 

• Germanischer Lloyd

 

• Lloyd´s Register of Shipping

 

• Registro Italiano Navale (pending)

 

• Russian Maritime Register of Shipping

 


 TOP