Applications
For fixed installations in communication, radio, control, and data processing facilities on ships and offshore units in all locations, on open decks and in safety circuits, where fire resistance is required.
The cables meet the fire characteristics acc. to IEC 60331-21 as well as the flame test requirements on bunched cables acc. to IEC 60332-3-22 and IEEE 45-18.13, and perform of the SOLAS requirements.
All cable materials are free of halogens. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, these cables are especially suitable for the installation on passenger ships.
Design
- Conductor: stranded bare copper (7 wires), class 2
- Insulation: HEPR (hardgrade ethylene propylene rubber)
- Laying up: pair stranding (2 pair cable=quad stranding)
- Armouring: separator tape, bare copper braid, separator tape (optional)
- Outer sheath: polyolefin, colour: orange
Marking
e.g.: l NEXANS l FMGCH-F 250 V 85°C DIN 89159 IEC 60092-375 IEC 60332-3-22 IEC 60331 HALOGENFREE 19x2x0,75 mm2 + Metric Marking
Core Identification
Colour of each pair: white-blue
The cores or each pair are printed with same numbers, starting in centre with number 1
|