Applications
For protected installation in railway vehicles (locomotives, trains, trolley busses), switching stations and control panels. Installation in cable ducts, pipes and tubes. Specially for mobile links between cars or car bogies.
This cable will be specially design in line to SNCF 10-5249-367 resp. SNCF 10-5315-848 resp. NFF 63 826 acc. to the customers demand.
Design
1. Conductor
Flexible or extra flexible stranded tinned copper, class 5 resp. 6
acc. to DIN VDE 0295 / IEC 60228 / HD 383,
conductor wrapping optional.
2. Insulation
Cross linked compounds
type EI104 (rubber) or
type EI112 (silicone)
3. Separtor
Tape or foil
4. Screen
Tinned Cu wire braid or
textil braid
5. Separator
Tape or foil
6. Sheath
cross linked compound type EM104, black
Testing procedures must be defined with the customers.
|