MAZ CHXOE multipair

Send link to this page print Your Nexans contact on this page
MAZ CHXOE multipair Cables for Rolling Stock
Standards
International  EN 50264-1; EN 50267-2-1; EN 50267-2-2; EN 50305; EN 50306-2.1; EN 50343; EN 60684-2
Description

Application

As a control cable in railway rolling stock with mineral oil and fuel resistance. With reference to EN 50306 – 4 with profile MM and with reference to cable class P.

 

Cable marking Example

A three core control cable with 1,0 mm² conductor cross-section, halogen free core insulation, a copper braid and a halogen free, flame retardant outer sheath, is designated as:

3 MAZ 1,0 C HXOE

 

Core colours

up to 10 cores colored; Core: 1 - white, 2 - brown, 3 - blue, 4 - black, 5 - red, 6 - yellow, 7 - green, 8 - grey, 9 - orange, 10 - violet; >10 cores: all cores white with numbers marking.

 

Standards

DIN 5510 part 1

Hazard level 1 - 4


 TOP
Characteristics
Construction characteristics
Halogen free PE sheathed  
Dimensional characteristics
Minimum insulation thickness 0.13mm  
Electrical characteristics
Rated Voltage Uo/U (Um) 300 / 300 V  
Usage characteristics
Max. conductor temperature in service 90°C  
Gases corrosivity No acc. to EN 50267-2-2  
Gases toxicity innocuous EN 50305  
Flame retardant EN 50305  
Smoke density EN/IEC 61034-2  

 TOP
Your selection
Number of pairs  
Conductor cross-section  mm²
Conductor diameter, range  mm
Diameter over external conductor / metallic screen  mm
Minimum outer sheath thickness  mm
Cable Diameter, range  mm
Approximate weight  kg/km
Fire load  kWh/m
Apply
Reset
Results   11/11
Select all Items Nexans ref. nb pairs Cross section (mm²) Conductor diam, range (mm) Diameter over external conductor / metallic screen (mm) Min. outer sheath thick. (mm) Cable diam. range (mm) Approx. weight (kg/km) Fire load (kWh/m)
Make to order product 45982010 2 0.5 0.8 .. 0.95 5.6 0.5 6.6 .. 7.4 76 0.18
Make to order product 45981710 3 0.5 0.8 .. 0.95 6.0 0.5 7.1 .. 7.9 89 0.21
Make to order product 45981910 4 0.5 0.8 .. 0.95 7.0 0.5 7.6 .. 8.5 106 0.23
Make to order product 45982110 6 0.5 0.8 .. 0.95 7.8 0.5 9 .. 9.9 143 0.31
Make to order product 45989310 12 0.5 0.8 .. 0.95 11.0 0.75 12.7 .. 13.5 267 0.53
Make to order product 45981810 2 0.75 1 .. 1.15 6.3 0.5 7.4 .. 8.2 96 0.21
Make to order product 45901010 4 0.75 1 .. 1.15 7.4 0.5 8.3 .. 9.2 138 0.28
Make to order product 45989810 2 1 1.1 .. 1.3 6.8 0.5 8 .. 8.8 111 0.23
Make to order product 45989610 3 1 1.1 .. 1.3 7.4 0.5 8.5 .. 9.3 135 0.26
Make to order product 45989910 2 1.5 1.45 .. 1.6 8.6 0.5 9.5 .. 10.5 153 0.33
Make to order product 45990010 6 1.5 1.45 .. 1.6 12.2 0.7 13.2 .. 14.2 342 0.577
Add to favorites

 TOP
Characteristica ELCURAIL MAZ CHXOE

Maximum admissible operating temperature at the conductor

Conductor in operation

≤ 90°C / 100,000 h

Application in cold areas

> - 40°C

Minimum admissible bending radii

fixed installation

D ≤ 12 mm ≥ 3 D

D > 12 mm ≥ 4 D

operation caused movement

 

D ≤ 12 mm ≥ 5 D

D > 12 mm ≥ 6 D

D = cable diameter

Operational Conditions

nominal voltage

3000 V

test alternating voltage ( core / core ) 1 minute

2000 V / AC

current carrying capacity

according to EN 50 343