Flamex Control-X (FC-X)

New
Send link to this page print Your Nexans contact on this page
Flamex Control-X (FC-X)
Standards
International  EN 50267-2-2; EN 50305; EN 50306; EN 50343; EN 60684-2
Description

Use

Thin wall connection core for use in electronic equipment.
For internal use for connection of equipment in railway rolling stock.
According to EN 50306 – 2, you have to take EN 50355 into account. 

Marking (for example)

x Nexans x Flamex Control - X EN 50306-2 300 V 1x1,5 M 

Standard National: Hazard Level 1-4
Standard International: EN  60332-1-2; EN 60332-3, EN 61034-2



Related documents
  FLAMEX Control-X (FC-X) Info  (2197.2kb)



 TOP
Characteristics
Construction characteristics
Halogen free PE sheathed  
Conductor material Tinned copper  
Insulation Polymer optical fiber + bare copper stranded conductor  
Conductor flexibility Fine stranded  
Electrical characteristics
Rated Voltage Uo/U (Um) 300 / 500 V  
Usage characteristics
Max. conductor temperature in service 105°C  
Gases corrosivity No acc. to EN 50267-2-2  
Gases toxicity innocuous EN 50305  
Flame retardant EN 50305  
Smoke density EN/IEC 61034-2  

 TOP
Your selection
Conductor cross-section  mm²
Conductor diameter, range  mm
Minimum insulation thickness  mm
Minimum outer diameter  mm
Maximum outer diameter  mm
Approximate weight  kg/km
Max. DC resistance of the conductor at 20°C  Ohm/km
Apply
Reset
Results   5/5
Select all Items Nexans ref. Cross section (mm²) Conductor diam, range (mm) Min. insulation thick. (mm) Min. outer diam. (mm) Max. outer diam. (mm) Approx. weight (kg/km) Max. DC resist. conductor 20°C (Ohm/km)
Make to order product 41300227   New 0.5 0.8 .. 0.95 0.18 1.15 1.45 6 40.1
Make to order product 41300327   New 0.75 1 .. 1.15 0.18 1.35 1.65 8 26.7
Make to order product 41300427   New 1 1.1 .. 1.3 0.18 1.45 1.8 11 20
Make to order product 41300527   New 1.5 1.45 .. 1.65 0.22 1.95 2.3 17 13.7
Make to order product 41300627   New 2.5 1.85 .. 2.15 0.28 2.5 2.85 27 8.21
Add to favorites

 TOP
Temperature/ radii

Maximum admissible operating temperature at conductor

 

Conductor in operation: 

≤ 105°C/ 100,000 h

Minimum admissible bending radii

 

Implementation

D ≥2 D

fixed installation

D ≥ 3 D

D = cable diameter

 

 

 

 

 