RHEYHALON 4GKW-EN FR 1,8/3 (3,6) kV

Send link to this page print Your Nexans contact on this page
RHEYHALON 4GKW-EN FR 1,8/3 (3,6) kV EN 50264-3-1, tab. 2 and EN 50200
Halogenfree single core cable with ciruit integrity (15 min)
1,8/3 kV
Standards
International  EN 50200; EN 50264-3-1
Description

Applications

For protected installation in railway vehicles (locomotives, trains, trolley busses), switching stations and control panels. Installation in cable ducts, pipes and tubes.
Current carrying capacity acc. to EN 50343 as well as VDE 0298 part 4.
Serves request acc. to EN 45545-1.
Fire integrity is in acc. with EN50200 (15 minutes) resp. EN 50362.

 

Design

1. Conductor

Flexible stranded tinned copper, class 5 acc. to DIN VDE 0295 / IEC 60228
/ HD 383, conductor wrapping optional.

2. Mica taping

3. Insulation

Double layer insulation, rubber type EI110/EI109 (EM104)  acc. to EN 50264-1,
oil, diesel-oil, ozone and UV-resistant

 

Cable marking

e.g.:    RHEYHALON VDE-Reg.-Nr. 7904 4GKW-EN FR 1,8/3 kV EN 50264-3-1 
           1800V  1x25 OM  FA-Nr. ...
 

Core colours

Black (BK)
 

Additional standards

DIN 5510 part 1: Flame protection class 1, 2, 3 and 4
BS 6853 (on request)


 TOP
Characteristics
Construction characteristics
Halogen free IEC 60754-1  
Usage characteristics
Operating temperature, range -40 .. 90°C  
Gases corrosivity No acc. to EN 50267-2-2  
Gases toxicity innocuous EN 50305-9.2  
Flame retardant EN 60332-1-2 & EN 60332-3-24 & EN 60332-3-25  
Smoke density EN/IEC 61034-2  
Standard EN  
Bending factor when installed 5(xD)  
Bending factor when laying 10(xD)  
Oil resistance Yes  
Ozone resistance Yes  
U.V resistance Yes  

 TOP
Your selection
Colour  
Conductor cross-section  mm²
Minimum outer diameter  mm
Maximum outer diameter  mm
Fire load  kWh/m
Approximate weight  kg/km
Apply
Reset
Results   11/11
Select all Items Nexans ref. Colour Cross section (mm²) Min. outer diam. (mm) Max. outer diam. (mm) Fire load (kWh/m) Approx. weight (kg/km)
Make to order product 79471436 Black 25 10.9 11.5 0.4 290
Make to order product 79471437 Black 35 12.0 12.5 0.46 400
Make to order product 79471438 Black 50 13.9 14.5 0.6 550
Make to order product 79471439 Black 70 15.9 16.5 0.75 750
Make to order product 79471440 Black 95 17.6 18.2 0.85 970
Make to order product 79471441 Black 120 19.9 20.5 1.1 1250
Make to order product 79471442 Black 150 22.2 22.8 1.35 1550
Make to order product 79471443 Black 185 24.1 24.7 1.5 1900
Make to order product 79471444 Black 240 27.2 27.8 1.9 2450
Make to order product 79471445 Black 300 29.9 30.7 2.2 3050
Make to order product 79471446 Black 400 34.7 35.5 3.5 4000
Add to favorites

 TOP
Electrical properties

Nominal voltage 

Uo/U (Umax) = 1,8/3 (3,6) kV

Max. operating voltage (d.c.)                                                         

Vo =2,7 kV 

Testing a.c. voltage (5 minutes)

U = 6,5 kV


Max. operating temperature at conductor

Conductor at normal operation

≤ 90 °C/250.000 h

 

≤ 120 °C/20.000 h

Overload 

≤ 160 °C / 50 h

Conductor under short-circuit conditions (tinned)

≤ 200 °C