FLAMEX Panto 26/45 kV (52 kV)

Send link to this page print Your Nexans contact on this page
FLAMEX Panto  26/45 kV (52 kV) In line with EN 50264 and NFF 16101
Halogenfree medium voltage cable
Standards
International  EN 50264
Description

Applications

For inside and outside use in railway vehicles. Installation in cable ducts and tubes.

Current-carrying capacity acc. to EN 50343. Satisfies performance requirements to Hazard Level 4 acc. to EN 45545-1.
 

On request available: completely pre-assembled flexible cables with plugs and sealing ends, electrically tested.

 

Design

1. Conductor
Flexible stranded tinned copper, acc. to IEC 60228 class 5.

2. Inner semi-conductive stress control layer
Conductive rubber

3. Insulation
HEPR, type EI 110 acc. to EN 50264-1,
high voltage compound, ozone resistant 

4. Outer semi-conductive insulation shield layer
Conductive rubber (Thermo-Strip)

5. Separtor
Tape

6. Screen
Single wires, tinned (Ø 0,6 mm), separator

7. Outer sheath
Special cross-linked EVA, type EM 104 acc. to EN 50264-1,
oil,  diesel-oil, ozone und uv resistant

Cable marking

Ink marking white e.g.:

FLAMEX Panto    DTREN 150 018  - SNCF 10-5299319  95/16 mm2 - Cue_F 
- S 26/52 kV   (ww/YYYY)   FA-Nr. ...

Addional Standards

 NF F 16-101


 TOP
Characteristics
Construction characteristics
Halogen free IEC 60754-1  
Electrical characteristics
Rated Voltage Uo/U (Um) 26 / 45 kV  
Usage characteristics
Operating temperature, range -40 .. 90°C  
Gases corrosivity No acc. to EN 50267-2-2  
Gases toxicity innocuous EN 50305-9.2  
Flame retardant EN 60332-1-2 & EN 60332-3-24 & EN 60332-3-25  
Smoke density EN/IEC 61034-2  
Bending factor when installed 6(xD)  
Bending factor when laying 10(xD)  
Oil resistance Yes  
Ozone resistance Yes  
U.V resistance Yes  

 TOP
Electrical properties

Nominal voltage

Uo/U (Umax) = 26/45 (54) kV

Max. operating voltage

Uo max = 32 kV

Test voltage                                                              Core/Screen (5 minutes)

Uo = 70 kV

Core/Screen (1 minutes)

Uo = 75 kV

Partial discharge measurement by 52 kV,  on pre-assembled flexible cable     

≤ 5 pC


Max. operating temperature at conductor

Conductor at normal operation

≤ 90 °C/250.000 h

 

≤ 120 °C/20.000 h

Overload 

≤ 160 °C / 50 h

Conductor under short-circuit conditions (tinned)

≤ 200 °C


 TOP