RHEYHALON (N)S2HXAFOE (3.6/6 kV)

Send link to this page print Your Nexans contact on this page
RHEYHALON (N)S2HXAFOE (3.6/6 kV) In line with EN 50382-2 and DIN VDE 0250 part 606 E
Halogenfree sheathed singel core cable for higher temperature applications

3,6/6 kV
Standards
International  EN 50382-2; Manufacturer specification
Description

Applications

For inside and outside use in railway vehicles (locomotives, trains, trolley busses, etc.), switching stations and control panels. Installation in cable ducts, tubes and outside.

For wiring in switching stations and distribution boards up to 1.000 V, this cable is short-circuit and earth fault save.

Current-carrying capacity acc. to EN 50343 as well as VDE 0298 part 4.Serves request with regard to Hazard Level 4 acc. to EN 45545-1

 
Design

1. Conductor

Flexible stranded tinned copper, acc. to DIN VDE 0295/IEC 60228/HD 383
class 5, conductor wrapping optonal

2. Insulation

High grade silicon type EI112 acc. to EN 50382-1

3. Outer sheath

High grade silicon, type EM107 acc. to EN 50382-1,
oil, diesel-oil, ozone and uv resistant

 

Cable marking

Marking white

RHEYHALON 180  (N)S2HXAFOE  3,6/6 kV  (EN) 50382-.2  3600V 1x50  OF

 

Core colours

yellow (YE)

 

Addional Standards

DIN 5510 part 1 Flame protection class 1, 2, 3 and 4; BS 6853


 TOP
Characteristics
Construction characteristics
Halogen free IEC 60754-1  
Usage characteristics
Operating temperature, range -65 .. 180°C  
Gases corrosivity No acc. to EN 50267-2-2  
Gases toxicity innocuous EN 50305-9.2  
Flame retardant EN 60332-1-2 & EN 60332-3-24 & EN 60332-3-25  
Smoke density EN/IEC 61034-2  
Bending factor when installed 6(xD)  
Bending factor when laying 10(xD)  
Oil resistance Yes  
Ozone resistance Yes  
U.V resistance Yes  

 TOP
Your selection
Colour  
Conductor cross-section  mm²
Minimum outer diameter  mm
Maximum outer diameter  mm
Fire load  kWh/m
Approximate weight  kg/km
Apply
Reset
Results   14/14
Select all Items Nexans ref. Colour Cross section (mm²) Min. outer diam. (mm) Max. outer diam. (mm) Fire load (kWh/m) Approx. weight (kg/km)
79470361 Yellow 4 9.4 10.4 0.27 140
79470362 Yellow 6 10.3 11.0 0.3 160
79470363 Yellow 10 11.4 12.0 0.34 210
79470364 Yellow 16 12.9 13.7 0.41 300
79470365 Yellow 25 14.7 15.5 0.52 400
79470366 Yellow 35 16.0 17.0 0.58 520
79470367 Yellow 50 17.5 18.5 0.65 650
79470368 Yellow 70 19.2 20.5 0.73 880
79470369 Yellow 95 21.5 22.5 0.89 1150
79470370 Yellow 120 23.5 24.5 1.03 1400
79470371 Yellow 150 24.7 27.0 1.12 1700
79470372 Yellow 185 26.9 28.5 1.21 2000
79470373 Yellow 240 29.5 31.0 1.35 2600
79470374 Yellow 300 31.7 33.5 1.48 3150
Add to favorites

 TOP
Electrical properties

Nominal voltage 

Uo/U (Umax) = 3.6/6 (7.2) kV

Max. operating voltage in d.c. installations, one-sided earthed                                                              

Uo= 6.5 kV DC

Testing a.c. voltage (5 minutes) 

U = 12.5 kV


Max. operating temperature at conductor

Conductor at normal operation

≤ 150 °C/100.000 h

 

≤ 180 °C/20.000 h

Conductor under short-circuit conditions (tinned)

≤ 350 °C


 TOP
Selling delivery information
  • Special conditions relating temperature and bending radii (e.g. by compelled guidance into cluthes, wagon transition and boogies) on request.


  • Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map