RHEYHALON (N)HXFAF 300/500 (550)V

Send link to this page print Your Nexans contact on this page
RHEYHALON (N)HXFAF 300/500 (550)V In line with EN 50264-3-1, tab. 1
Halogenfree control cable
300/500 V
Standards
International  EN 50264-3-1; Manufacturer specification
Description

Applications

For inside wiring in railway vehicles (locomotives, trains, trolley busses), switching stations and control panels.
Current carrying capacity acc. to EN 50343 as well as VDE 0298 part 4.
Serves request acc. to EN 45545-1

 

Design

1. Conductor

Flexible stranded tinned copper, class 5 acc. to DIN VDE 0295 / IEC 60228
/ HD 383

2. Insulation

Special cross-linked EVA, rubber type EI107 acc. to EN 50264-1, oil resistant

 

Cable marking

e.g.: RHEYHALON VDE-Reg.-Nr. 7626 (N)HXFAF 1,5mm² 300/500 V  FA-Nr. ...
 

Core colours

Black (BK); green/yellow (GNYE); other colours on request
 

Additional standards

DIN 5510 part 1: Flame protection class 1, 2, 3 and 4
 


 TOP
Characteristics
Construction characteristics
Halogen free IEC 60754-1  
Usage characteristics
Operating temperature, range -40 .. 90°C  
Gases toxicity innocuous EN 50305-9.2  
Standard EN  
Bending factor when installed 3(xD)  
Bending factor when laying 5(xD)  
Oil resistance Yes  
Ozone resistance Yes  
U.V resistance Yes  

 TOP
Your selection
Colour  
Conductor cross-section  mm²
Minimum outer diameter  mm
Maximum outer diameter  mm
Fire load  kWh/m
Approximate weight  kg/km
Gases corrosivity  
Flame retardant  
Smoke density  
Apply
Reset
Results   6/6
Select all Items Nexans ref. Colour Cross section (mm²) Min. outer diam. (mm) Max. outer diam. (mm) Fire load (kWh/m) Approx. weight (kg/km) Gases corrosivity Flame retardant Smoke density
79474001 Black 0.5 1.7 1.9 0.015 7 No EN 50265-2-1 EN 50268
79474101 Black 0.75 1.8 2.0 0.018 9.5 No EN 50265-2-1 EN 50268
79474201 Black 1 2.1 2.3 0.021 12 No EN 50265-2-1 EN 50268
79474301 Black 1.5 2.4 2.8 0.025 17.5 No EN 50265-2-1 EN 50268
79474401 Black 2.5 2.8 3.2 0.033 26.5 No EN 50265-2-1 EN 50268
79474501 Black 4 3.5 3.9 0.04 40 No EN 50265-2-1 EN 50268
Add to favorites

 TOP
Electrical properties

Nominal voltage 

Uo/U (Umax) = 300/500 (550) V

Max. operating voltage (d.c.)                                                         

Uo = 450 V DC

Testing a.c. voltage (5 minutes) 

U = 2 kV


Max. operating temperature at conductor

Conductor at normal operation

≤ 90 °C/250.000 h

 

≤ 120 °C/20.000 h

Overload 

≤ 160 °C / 50 h

Conductor under short-circuit conditions (tinned)

≤ 200 °C