WINDLINK® LS0H UL/CSA EPR/XLEVA 600V 90°C

Send link to this page print Your Nexans contact on this page
WINDLINK® LS0H UL/CSA EPR/XLEVA 600V 90°C

Appliance Wiring Material UL 758 standard certified
600 V +90°C
Style 3835 for single cores & Style 4552 for multi-cores
UL/CSA 22.2
AWM class I, II, or I / II , Group A,B, or A/B

UL CSA
Description

Application

This cable is specially designed for Wind Turbines

The quality of material used for insulation and sheathing and high quality copper conductors make the cables both flexible, durable, resistant to torsion and to high temperatures. Nexans offers more than a decade of experience in the wind energy market. Our expertise makes WINDLINK® cables highly recommended for wind turbines.

 

Main characteristics

  • Frequent torsion: Excellent torsion behavior
  • Industrial cables resistant to high temperatures
  • Heavy duty
  • Temperature on core: 90°C in normal use; 250°C in short circuit
  • Water resistance: AD2, AD6
  • Corrosive and polluting substances resistance: AF3
  • Outdoor use : temporary and permanent
  • Impact resistance: AG2
  • Oil resistant ASTM/IRM 902 and special oils used in Wind machines
  • UV resistant for external application
  • Ozone resistant
  • Fire performances (IEC/EN 60332-1, EN 50265-1 and 2-1 )

 

Design 

1. Conductor :
Annealed plain copper-  Optional tape
Flexible (fine wire class 5 of IEC/EN 60228

2. Insulation :
Special thermoset EPR for high temperature
Optional tape on insulation or assembling

3. Sheath:
High mechanical performance , oil resistant
Ozone resistant, ref HD 22.1, black colour
Special thermoset XLEVA, halogen free rubber improved for low temperature behaviour (-40°C)
 


 TOP
Characteristics
Construction characteristics
Conductor material Plain annealed copper  
Electrical characteristics
Rated Voltage Uo/U (Um) 600 V  
Mechanical characteristics
Torsion test max. +/- 4 turns for 10 meters max:150° per meter  
Mechanical resistance to impacts Good  
Mechanical stress 15N/mm2  
Usage characteristics
Smoke density LSF EN 61034-2  
U.V resistance Very good  
Flame retardant NFC 32070 C2, IEC 60332-1-2  
Watertightness AD2 to AD6  
Oil resistance Good  
Ambient installation temperature, range -40 .. 80°C  
Ambient dynamic operating temperature, range -40 .. 50°C  
Ambient static operating temperature, range -40 .. 50°C  
Operating temperature, range -40 .. 90°C  
Minimum operating temperature -40°C  
Max. conductor temperature in service 90°C  
Short-circuit max. conductor temperature 250°C  

 TOP
Your selection
Conductor cross-section  mm²
Number of cores  
Outer Diameter as per Standard Min Max  mm
Outer diameter acc Windturbines needs Min Max  mm
Apply
Reset
Results   4/4
Select all Items Nexans ref. Cross section (mm²) Nb. of cores Outer diam. Standard min max (mm) Outer diam. Wind Min Max (mm)
1 x 35 7.6 1 15.5 .. 18.5
1 x 185 18 1 28.0 .. 32.0
4 G 1.5 1.5 4 11.7 .. 14.0
4 G 35 7.6 4 32.5 .. 40.0
Add to favorites

 TOP
Complementary technical for Windlink®

Usage characteristics:

Mechanical stress :

(on the whole cable, per mm² of a cross section of plain copper core)

  • In normal use : 15 N/mm²

 

Mechanical characteristics:

Bending Radius

Mobile use = 6 x External diameter.
Static use = 3 x External diameter , if the external diameter < 12mm, 4 x if the external diameter >12 mm.

 

Electrical characteristics:

Permissible current rating: 

  • Permanent temperature of operation on the core 90°C
  • Ambient temperature for an outdoor installation  30°C

 

Correction factors according for other ambient temperature : according to IEC 60364.5.523 table 52.D1 or DIN VDE 0298-4 Table 15

Ambient
temperature (°C)
10 15 20 25 30 35 40 45 50 55 60 65 70 75
factors  1.17 1.13 1.09 1.04 1 0.96 0.91 0.87 0.82 0.76 0.69 0.62 0.54 0.45

The Voltage drop has been determined with Cos φ= 0.8

 

 Short circuit : constant K=139 Amps for 1 second, acc.to IEC 60949 ( short circuit temperature +250°C and conductor temperature +90°C)

 

 


 TOP
WINDLINK® LS0H UL758 / CSA 22.2

Other properties

Standard tests according to UL 758 standard style 3835 (single core), style 4552 (multi-core cables)
UV resistant sheath black sheath is UV resistant for external application
Oil resistant sheath good in oils, greases, gear box oil, etc
  • ASTM/IRM 902
24h at 100°C
  • Gear box oil as Tribol 1710/320 or equiv oil.
72h at 40°C or 24 h at 100°C
  • Hydraulic oil as Mobil DTE 13m or equiv oil. 
72h at 40°C or 24 h at 100°C

 TOP
Selling delivery information

Marking

WINDLINK® LS0H NEXANS 213
Nb cores X (or G) S
X = without G/Y
G = with G/Y
S = cross section (mm2)
+ "UL/CSA" marking
Week + year manufacturing
meter marking

 

Insulated Cores identification

• 1 core = Black (preferential)
• 2 cores = Brown + Blue
• 3 cores = Green/Yellow +Blue + Brown (G)
Brown + Black + Grey (X S>4mm²)
Blue + Brown + Black (X S 1.5 & 2.5 mm²)
• 4 cores = Green/Yellow + Brown + Black + Grey (G)
Blue + Brown + Black + Grey (X S 1.5 & 2.5 mm²)


Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map