2Y(st)H mbzh grey Signal cable
Standards
International  IEC 60332-1
National  DIN VDE 0207
Description

Application

2Y(st)H LSZH Signal cable for measurement, regulation and control applications in low voltage installations. The metallised foil protects against interference with external electrical fields.

 

Description

  1. Solid plain copper conductor, 0.6 or 0.8 mm
  2. PE conductor insulation
  3. Conductors bunched into pairs (except for 2p = 1quad)
  4. Pairs laid up in concentric layers
  5. Plastic separating foil over cable core
  6. Metallised foil over drain wire
  7. Fire retardant grey LSZH outer sheath (IEC 60332-1)

 

Marking

NEXANS AFG.SIGNAALKABEL 2Y(st)H mbzh nx2xs mm HALOGEENVRIJ OF°°°°°°

n = no. of pairs, s = diameter in mm, OF = traceability code
Metric marking

 

Core Identification

according NEN 1597 (see technical data, table B)


 TOP
Characteristics
Construction characteristics
Conductor material Plain copper  
Conductor flexibility Solid  
Insulation PE  
Screen Aluminium-PET with drain wire  
Outer sheath LSZH  
Sheath colour Grey  
Electrical characteristics
Maximal capacity at 800Hz 120nF/km  
Capacitance unbalance pair to pair 3000pF/km  
Capacitance unbalance pair to ground 3000pF/km  
Ohmical resistance of the insulation 100MOhm.km  
Breakdown voltage 0.8kV  
Maximum operating voltage 300V  
Mechanical characteristics
Mechanical resistance to impacts Normal domestic use  
Usage characteristics
Field of application Indoor  
Bending factor when laying 10(xD)  
Ambient installation temperature, range -5 .. 50°C  
Operating temperature, range -30 .. 70°C  
Resistance to vibrations No  

 TOP
Your selection
Conductor diameter  mm
Number of pairs  
Nominal outer diameter  mm
Apply
Reset
Results   11/11
Select all Items Nexans ref. Name Conductor diam. (mm) nb pairs Nom. outer diam. (mm)
10191744 2Y(st)H mbzh 1X2X0.8 mm grey (B500) 0.8 1 3.5
10179691 2Y(st)H mbzh 1X4X0.8 mm grey (D100) 0.8 2 4.4
10188642 2Y(st)H mbzh 1X4X0.8 mm grey (B500) 0.8 2 4.4
10194124 2Y(st)H mbzh 2X2X0.8 mm grey (B500) 0.8 2 5.9
10191513 2Y(st)H mbzh 3X2X0.8 mm grey (B500) 0.8 3 6.0
10191645 2Y(st)H mbzh 4X2X0.8 mm grey (B500) 0.8 4 6.3
10191750 2Y(st)H mbzh 6X2X0.8 mm grey (B500) 0.8 6 7.3
10201471 2Y(st)H mbzh 8X2X0.8 mm grey 0.8 8 8.15
10191813 2Y(st)H mbzh 10X2X0.8 mm grey (B500) 0.8 10 8.75
10191875 2Y(st)H mbzh 16X2X0.8 mm grey 0.8 16 10.7
10191897 2Y(st)H mbzh 24X2X0.8 mm grey 0.8 24 12.75
Add to favorites

 TOP
Table B colour code NEN 1597 (paired)

pair no.

A

B

pair no.

A

B

pair no.

A

B

1

white

red

13

white-blue

yellow

25

white-green

black

2*

white

blue

14

white-blue

green

26

white-black

red

3

white

yellow

15

white-blue

black

27

white-black

blue

4

white

green

16

white-yellow

red

28

white-black

yellow

5

white

black

17

white-yellow

blue

29

white-black

green

6

white-red

red

18

white-yellow

yellow

30

white-black

black

7

white-red

blue

19

white-yellow

green

 

 

 

8

white-red

yellow

20

white-yellow

black

 

 

 

9

white-red

green

21

white-green

red

 

 

 

10

white-red

black

22

white-green

blue

 

 

 

11

white-blue

red

23

white-green

yellow

 

 

 

12

white-blue

blue

24

white-green

green

 

 

 

Counting of the pairs starts in the centre of the cable. In case a cable contains more than 30 pairs,coding of pair 31 starts as of pair 1, etc. Only the last cycle may be incomplete.* = In case of a star-quad: red, blue, yellow, green

 TOP
Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map