FMGCH 150/250 V

Send link to this page print Your Nexans contact on this page
FMGCH 150/250 V Halogen Free Communication Cables with screen (armour) 150/250 V
Standards
International  IEC 60092-375; IEC 60332-3; IEC 60754-1; IEC 60754-2; IEC 61034
National  DIN 89159/98
Description

Applications

For fixed installations in communication, radio, control anddata processing facilities on ships and offshore units in alllocations and on open decks.

The cables meet the flame test requirements for bunched cablesacc.to IEC 60332-3 and IEEE 45-18.13, and perform to the SOLASrequirements.

All cable materials are free of halogens. This design ensuresthat non corrosive and low toxic gases emitted in case of fire.Therefore, these cables are especially suitable for installation onpassenger ships.

 

Design

  1. Conductor: stranded bare copper (7 wires)
  2. Insulation: HEPR (cross linked hardgrade ethylene propylenerubber)
  3. Laying up: pair stranding (2 pair cable=quad stranding)
  4. Armouring: separator tape, bare copper braid, separator tape(optional)
  5. Outer sheath: polyolefin, colour: black

 

Marking

e.g.: l NEXANS l FMGCH 250 V 85°C DIN 89159 IEC 60092-375 IEC 60332-3-22 HALOGENFREE 19x2x0,75 mm2 + Metric Marking

 

Core Identification

Colours of each pair: white/blue.
The cores or each pair are printed with same numbers, starting in centre with number 1.


 TOP
Characteristics
Construction characteristics
Conductor material Bare copper  
Conductor flexibility Stranded class 2  
Insulation HEPR  
Armour type Bare copper braid  
Outer sheath Polyolefin  
Sheath colour Black  
Halogen free IEC 60754-2  
Electrical characteristics
Test voltage 1500V  
Rated Voltage Uo/U (Um) 150 / 250 V  
Usage characteristics
Max. conductor temperature in service 85°C  
Short-circuit max. conductor temperature 250°C  
Minimum installation temperature -10°C  
Minimum operating temperature -35°C  
Flame retardant IEC 60332-3 Cat. A  
Gases corrosivity IEC 60754-2  
Smoke density IEC 61034  
Gases toxicity No toxicity to IEC 60754-1  
Electro magnetic interference resistance Yes  

 TOP
Additional Cable Characteristics

Minimum internal bending radius

 

- For all diameter

6 x cable diameter

 

 

Conductor resistance

≤ 26.0 Ohm / km

Insulation resistance

> 1100 MOhm x km

Transfer impedance at 10 MHz

 

1- and 2- pair cable

< 80 mOhm / m

4-pair cable

< 60 mOhm / m

7- to 24-pair cable

< 50 mOhm / m

 

 

Current ratings for continuous operation and further hints for cable installation

 

are according to IEC 60092-352

 


Approval

Type Approval Certificates   

 

• American Bureau of Shipping

 

• Bureau Veritas

 

• Det Norske Veritas 

 

• Germanischer Lloyd

 

• Lloyd´s Register of Shipping

 

• Registro Italiano Navale (pending)

 

• Russian Maritime Register of Shipping

 


 TOP