MPRX® 150/250 (300)V - 0.6/1 (1.2) kV

Send link to this page print Your Nexans contact on this page
MPRX® 150/250 (300)V - 0.6/1 (1.2) kV This product is part of our Shiplink® offer
Standards
International  IEC 60092-350; IEC 60092-351; IEC 60092-353; IEC 60092-359; IEC 60228; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Description

Application

MPRX® type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards 60092-352.

MPRX® type withstands the IEC 60332-3-22 fire test on bunched cables and performs to the SOLAS requirements.

Design

All materials used to manufacture this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships.

  1. Conductor:
    • Stranded bare copper class 2
    • (Sector-shapped: >/= 70 mm² 3 cores)
  2. Insulation: XLPE (cross linked polyethylene)
  3. Outer sheath:
    • Filler if necessary
    • Polyolefin
    • SHF2 on request
    • Colour: black for 0.6/1kV cables
                 grey for 150/250V cables

Type Approval Certificates

American Bureau of Shipping

Bureau Veritas

China Classification Society

Det Norske Veritas

Germanischer Lloyd

Lloyd's Register of Shipping

Registro Italiano navale

 

Marking

 

NEXANS 205 MPRX "voltage" "n" x(or G) "s" mm² 90C IEC 60332-3-22 "WW/YY" *CE* PN +Metric Marking*


 TOP
Characteristics
Construction characteristics
Conductor material Bare copper  
Insulation XLPE (Cross-linked Polyethylene)  
Material of filler / inner sheath Filler if necessary  
Outer sheath Polyolefin  
Halogen free IEC 60754-1  
Conductor flexibility Stranded class 2  
Usage characteristics
Fire retardant IEC 60332-3-22  
Smoke density IEC 61034  
Gases toxicity No  
Gases corrosivity IEC 60754-2  
Max. conductor temperature in service 90°C  
Operating temperature, range -30 .. 80°C  
Standard IEC  

 TOP
Your selection
Nominal outer diameter  mm
Approximate weight  kg/km
With Green/Yellow core  
Conductor shape  
Conductor cross-section  mm²
Number of cores  
Apply
Reset
Results   62/62
Select all Items Nexans ref. Country ref. Name Nom. outer diam. (mm) Approx. weight (kg/km) Green/ Yellow core
10164469 10164469 MPRX 0.6/1KV 7X1.5 11.1 190 No
10193617 10193617 MPRX 150/250V 7X0.75 8.3 100 No
10164483 10164483 MPRX 0.6/1KV 7X2.5 12.8 280 No
10164482 10164482 MPRX 0.6/1KV 5X2.5 11.5 210 No
10164468 10164468 MPRX 0.6/1KV 5X1.5 10.2 160 No
10193616 MPRX 150/250V 5X0.75 7.67 80 No
10196222 10196222 MPRX 0.6/1KV 1X10 7.1 130 No
10164429 10164429 MPRX 0.6/1KV 1X1.5 4.91 40 No
10164524 10164524 MPRX 0.6/1KV 1X95 17.2 1030 No
10164522 10164522 MPRX 0.6/1KV 1X70 14.5 770 No
10164488 10164488 MPRX 0.6/1KV 1X6 6.3 90 No
10164520 10164520 MPRX 0.6/1KV 1X50 12.4 560 No
10164518 10164518 MPRX 0.6/1KV 1X35 11.1 400 No
10164515 10164515 MPRX 0.6/1KV 1X25 10.1 300 No
10164503 10164503 MPRX 0.6/1KV 1X240 26.8 2530 No
10164477 10164477 MPRX 0.6/1KV 2X2.5+E Green 9.52 140 Yes
10164476 10014447 MPRX 0.6/1KV 3G2.5 9.52 140 Yes
10164475 10164475 MPRX 0.6/1KV 2X2.5 9.0 100 No
10164510 10164510 MPRX 0.6/1KV 2X16 15.0 450 No
10164505 10164505 MPRX 0.6/1KV 2X10 12.6 300 No
10164433 10164433 MPRX 0.6/1KV 2X1.5+E Green 8.26 90 Yes
10164430 10164430 MPRX 0.6/1KV 2X1.5 7.82 70 No
10164432 10009510 MPRX 0.6/1KV 3G1.5 8.26 90 Yes
10193582 10193582 MPRX 150/250V 2X0.75 6.2 50 No
10164471 10164471 MPRX 0.6/1KV 19X1.5 17.5 480 No
10193619 MPRX 150/250V 19X0.75 13.0 250 No
10164470 10164470 MPRX 0.6/1KV 12X1.5 14.9 320 No
10193618 MPRX 150/250V 12X0.75 10.9 170 No
10164474 10164474 MPRX 0.6/1KV 1X2.5 5.4 50 No
10164535 10164535 MPRX 0.6/1KV 1X185 23.6 1970 No
10164509 10164509 MPRX 0.6/1KV 1X16 8.2 190 No
10164531 10164531 MPRX 0.6/1KV 1X150 21.4 1610 No
10164526 10164526 MPRX 0.6/1KV 1X120 19.3 1290 No
10193583 MPRX 150/250V 3X0.75 6.52 60 No
10164504 10164504 MPRX 0.6/1KV 4X6 12.7 320 No
10196871 MPRX 0.6/1KV 4X35 24.6 1590 No
10199704 10199704 MPRX 0.6/1KV 2X25 18.6 690 No
10164484 10164484 MPRX 0.6/1KV 2X4 10.2 140 No
10164489 10164489 MPRX 0.6/1KV 2X6 10.8 200 No
10164464 MPRX 0.6/1KV 3X1.5 8.26 90 No
10164465 MPRX 0.6/1KV 4G1.5 9.22 120 Yes
10164506 MPRX 0.6/1KV 3X10 13.3 380 No
10164530 MPRX 0.6/1KV 3X120 SECT 33.5 3930 No
10164511 MPRX 0.6/1KV 3X16 15.9 580 No
10164478 MPRX 0.6/1KV 3X2.5 9.52 140 No
10164479 MPRX 0.6/1KV 4G2.5 10.4 170 Yes
10164516 MPRX 0.6/1KV 3X25 19.8 880 No
10164519 MPRX 0.6/1KV 3X35 22.1 1260 No
10164485 MPRX 0.6/1KV 3X4 10.8 190 No
10164466 10164466 MPRX 0.6/1KV 4X1.5 9.22 120 No
10164467 10164467 MPRX 0.6/1KV 5G1.5 10.2 160 Yes
10164508 10164508 MPRX 0.6/1KV 4X10 14.9 500 No
10164513 10164513 MPRX 0.6/1KV 4X16 17.7 770 No
10164481 10164481 MPRX 0.6/1KV 4X2.5 10.4 170 No
10164517 10164517 MPRX 0.6/1KV 4X25 22.0 1170 No
10164521 MPRX 0.6/1KV 3X50 24.9 1780 No
10164491 MPRX 0.6/1KV 3X6 11.6 250 No
10164523 MPRX 0.6/1KV 3X70 SECT 26.5 2360 No
10164525 MPRX 0.6/1KV 3X95 SECT 30.0 3120 No
10164473 10164473 MPRX 0.6/1KV 37X1.5 23.9 880 No
10164487 10164487 MPRX 0.6/1KV 4X4 12.0 240 No
10164472 10164472 MPRX 0.6/1KV 27X1.5 21.0 660 No
Add to favorites

 TOP
Selling delivery information

Core identification

For voltage 150/250 (300) V

white with black printed numbers

For voltage 0.6 / 1 (1.2) kV

  • 1 core : black
  • 2 cores : brown - blue
  • 2 cores+E : brown - blue - green/yellow
  • 3 cores : black - grey - brown
  • 3 cores+E : black - grey - brown - green/yellow
  • 4 cores : black - grey - brown - blue
  • 4 cores+E : blue - black - grey - brown - green / yellow
  • from 5 cores : white with black printed numbers

Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map