MAIN CHARACTERISTICS
Flexible and lightweight serie of cables with FEP + superpolyamide insulation for use in bundles. Abrasion resistance: medium. They are fire retardant (to NFC 32070/C1 French specification). They withstand most chemical fluids except for concentrated nitric acid.
STANDARDS
To AIR 4524 and MIL-W 5086B/7A specifications. These cables are approved by the Air Ministry under letters: N° 34722 STA/EQ/E2 (18-4-69) for AWG 24 N° 41763 STA/EQ/E2 (12-11-68) for AWG 22 up to AWG 12 Registered at B.N.Ae : N° 6412 420 A .
TECHNICAL REQUIREMENTS AND CONTROL CONDITIONS
Screen: to MIL.C. 7078C (August1971) U.S. specification.
COLOUR CODING
To Air 0107 A (October 1961) and note N° 348/SIB distributed under N° 5927/STT/SIB (3-05-1961). .
CONSTRUCTION
BASE CORE: 1806
- CONDUCTOR
stranded tinned copper wires or stranded tinned copper alloy wires for the cross section area 0.21 mm
- INSULATION
fluoropolymer (FEP)
- OUTER JACKET
superpolyamide (radial thickness: from 0.10 mm up to 0.15 mm)
-
806
- LAY UP
1 or several 1806 cores
- SCREEN
tinned copper braid (Kr ³ 62%)
- OUTER JACKET
superpolyamide (radial thickness: about 0.20 mm)
|